Kai Liang, Saimeng Jin, Hengzhi Chen, 等. Parametric optimization of packed bed for activated coal fly ash waste heat recovery using CFD techniques[J]. 中国化学工程学报(英文版), 2020,28(2):518-525.
Kai Liang, Saimeng Jin, Hengzhi Chen, Jingzheng Ren, Weifeng Shen, Shun'an Wei. Parametric optimization of packed bed for activated coal fly ash waste heat recovery using CFD techniques[J]. Chinese Journal of Chemical Engineering, 2020, 28(2): 518-525.
Kai Liang, Saimeng Jin, Hengzhi Chen, 等. Parametric optimization of packed bed for activated coal fly ash waste heat recovery using CFD techniques[J]. 中国化学工程学报(英文版), 2020,28(2):518-525.DOI: 10.1016/j.cjche.2019.06.004.
Kai Liang, Saimeng Jin, Hengzhi Chen, Jingzheng Ren, Weifeng Shen, Shun'an Wei. Parametric optimization of packed bed for activated coal fly ash waste heat recovery using CFD techniques[J]. Chinese Journal of Chemical Engineering, 2020, 28(2): 518-525.DOI: 10.1016/j.cjche.2019.06.004.
Parametric optimization of packed bed for activated coal fly ash waste heat recovery using CFD techniques
Coal fly ash is an industrial solid waste generated from coal preparation during the processing and cleaning of coal for electric power generation. Comprehensive investigation on the reutilization of waste heat of activated coal fly ash is of great economic significance. The method of recovering the waste heat
proposed in this study
is the transfer of heat from activated coal fly ash to gas with the movement of air using the packed bed
providing valuable energy sources for preheating the raw coal fly ash to reduce the overall energy consumption. The investigation is carried on the heat transfer characteristics of gas-solid (activated coal fly ash) phases and air temperature fields of the packed bed under some key conditions
via
computational fluid dynamics. A two dimensional geometry is utilized to represent key parts of packed bed. The distribution mechanism of the temperature field for gas phase is analyzed based on the transient temperature contours at different times. The results show that the obtained rule of gas-solid heat transfer can effectively evaluate the influences of operating parameters on the air temperature in the packed bed. Simultan
eously
it is found that no temperature differences exist in the hot air at the outlet of the packed bed. The investigation provides guidance for the design and optimization of other similar energy recovery apparatuses in industries.
关键词
Keywords
references
The trial reading is over, you can activate your VIP account to continue reading.