P. Soleimani, M. Khoshvaght-Aliabadi, H. Rashidi, 等. Performance enhancement of water bath heater at natural gas city gate station using twisted tubes[J]. 中国化学工程学报(英文版), 2020,28(1):165-179.
P. Soleimani, M. Khoshvaght-Aliabadi, H. Rashidi, H. Bahmanpour. Performance enhancement of water bath heater at natural gas city gate station using twisted tubes[J]. Chinese Journal of Chemical Engineering, 2020, 28(1): 165-179.
P. Soleimani, M. Khoshvaght-Aliabadi, H. Rashidi, 等. Performance enhancement of water bath heater at natural gas city gate station using twisted tubes[J]. 中国化学工程学报(英文版), 2020,28(1):165-179.DOI: 10.1016/j.cjche.2019.03.018.
P. Soleimani, M. Khoshvaght-Aliabadi, H. Rashidi, H. Bahmanpour. Performance enhancement of water bath heater at natural gas city gate station using twisted tubes[J]. Chinese Journal of Chemical Engineering, 2020, 28(1): 165-179.DOI: 10.1016/j.cjche.2019.03.018.
Performance enhancement of water bath heater at natural gas city gate station using twisted tubes
Natural gas is transported from producing regions to consumption regions by using transmission pipelines at high pressures. At consumption regions
the pressure of natural gas is reduced in city gate stations (CGSs). Before the pressure reduction process
the temperature of natural gas is increased usually by using a water bath heater
which burns natural gas as fuel
to protect against freezing of natural gas. These types of heat exchangers have a low efficiency and consume a lot of fuel to generate the required heat. In the current study
the twisted configuration of the heating coil is proposed and investigated to enhance the heat transfer through a water bath heater with a nominal capacity of 1000 m
3
·h
-1
. Firstly
the implementation procedure is validated with data collected from the CGS of Qaleh-Jiq (located in Golestan province of Iran). A very good agreement is achieved between the obtained results and the real data. Then
three different twist ratios are considered to examine the twisting effects. The proposed technique is evaluated in the terms of velocity
temperature
and pressure variations
and the results are compared with the conve
ntional case
i.e
. straight configuration. It is found that both the heat transfer rate and the pressure drop augment as the twist ratio is raised. Finally
it is concluded that the twisted tubes can reduce the length of the gas coil by about 12.5% for the model with low twist ratio
18.75% for the model with medium twist ratio
and 25% for the model with high twist ratio as compared to the straight configuration.
关键词
Keywords
references
The trial reading is over, you can activate your VIP account to continue reading.