Ming Lei, Jing Hai, Jiang Cheng, 等. Variation of toxic pollutants emission during a feeding cycle from an updraft fixed bed gasifier for disposing rural solid waste[J]. 中国化学工程学报(英文版), 2018,26(3):608-613.
Ming Lei, Jing Hai, Jiang Cheng, Jiawei Lu, Jieru Zhang, Tao You. Variation of toxic pollutants emission during a feeding cycle from an updraft fixed bed gasifier for disposing rural solid waste[J]. Chin.J.Chem.Eng., 2018, 26(3): 608-613.
Ming Lei, Jing Hai, Jiang Cheng, 等. Variation of toxic pollutants emission during a feeding cycle from an updraft fixed bed gasifier for disposing rural solid waste[J]. 中国化学工程学报(英文版), 2018,26(3):608-613.DOI: 10.1016/j.cjche.2017.07.019.
Ming Lei, Jing Hai, Jiang Cheng, Jiawei Lu, Jieru Zhang, Tao You. Variation of toxic pollutants emission during a feeding cycle from an updraft fixed bed gasifier for disposing rural solid waste[J]. Chin.J.Chem.Eng., 2018, 26(3): 608-613.DOI: 10.1016/j.cjche.2017.07.019.
Variation of toxic pollutants emission during a feeding cycle from an updraft fixed bed gasifier for disposing rural solid waste
The variation of toxic pollutants emission during a feeding cycle was examined by field monitoring from a batch feeding updraft fixed bed gasifier for disposing rural domestic solid waste. Results showed that the content of oxygen in flue gas gradually increased
while SO
2
and HCl in flue gas decreased with time after feeding in a whole feeding cycle. Although large amount of CO was produced during the gasifying
low CO content in flue gas could be obtained after the heat treatment with an electric heating device. The distribution characteristics of dioxin congeners in flue gas indicted the re-synthesis of dioxins after flue gas heating
and the increase of oxygen promoted the synthesis of dioxins. The emission content of dioxins could meet the standard (0.1 ng I-TEQ·m
-3
GB18458-2014) of China when the oxygen content was controlled below 8.3%. Hence
for a batch feeding gasifier
low oxygen condition should be offered by reducing air intake at the later stage of feeding cycle in order to decrease the re-synthesis of dioxins after the flue gas heating.