removal from biogas by water washing system was investigated with various parameters
including liquid/gas ratio
pressure
temperature
and CO
2
content. The results indicate that CO
2
removal ratio could reach 34.6%- 94.2% as liquid/gas ratio increased from0.14 to 0.50. Increasing pressure (from0.8 to 1.2MPa) could improve gas purification with a constant inflow rate of gas. Temperature played a key role in the process and lower temperature in absorption tower was beneficial for reducing CO
2
content. CO
2
removal ratio could reach 24.4%-83.2% when CO
2
content in the simulated gas was 25%-45%. The lowest CO
2
content after absorption was 2.6% at 1.2MPawith 400 L·h
-1
gas flowand 200 L·h
-1
water flow
whichmeets the requirement of CO
2
content in natural gas for vehicle fuel.
关键词
Keywords
references
The trial reading is over, you can activate your VIP account to continue reading.
The effect of membrane pores wettability on CO2 removal from CO2/CH4 gaseous mixture using NaOH, MEA and TEA liquid absorbents in hollow fiber membrane contactor
Unraveling the methane decomposition mechanism on Fe-Ni-Ca-O composite catalysts: A combined density functional theory and microdynamic study
CO2 capture by ternary ionic liquid non-aqueous phase change solvents
Experimental and numerical studies of holdup and velocity behavior for inclined bubbly oil-water pipe flows
Synthesis of chemiluminescent carbonized polymer dots under atmospheric conditions for multimode luminescence anti-counterfeiting
相关作者
Ali Taghvaie Nakhjiri
Amir Heydarinasab
Omid Bakhtiari
Toraj Mohammadi
相关机构
2 Membrane Research Center, Faculty of Chemical and Petroleum Engineering, Razi University, Kermanshah
3 Research Center for Membrane Separation Processes, Faculty of Chemical Engineering, Iran University of Science and Technology(IUST), Narmak, Tehran