Sompol Skullong, Pongjet Promvonge. Experimental Investigation on Turbulent Convection in Solar Air Heater Channel Fitted with Delta Winglet Vortex Generator[J]. 中国化学工程学报(英文版), 2014,22(1):1-101004-954160030-6.
Sompol Skullong, Pongjet Promvonge. Experimental Investigation on Turbulent Convection in Solar Air Heater Channel Fitted with Delta Winglet Vortex Generator[J]. Chin.J.Chem.Eng., 2014, 22(1): 1-10.
Sompol Skullong, Pongjet Promvonge. Experimental Investigation on Turbulent Convection in Solar Air Heater Channel Fitted with Delta Winglet Vortex Generator[J]. 中国化学工程学报(英文版), 2014,22(1):1-101004-954160030-6.DOI: 10.1016/S1004-9541(14)60030-6.
Sompol Skullong, Pongjet Promvonge. Experimental Investigation on Turbulent Convection in Solar Air Heater Channel Fitted with Delta Winglet Vortex Generator[J]. Chin.J.Chem.Eng., 2014, 22(1): 1-10.DOI: 10.1016/S1004-9541(14)60030-6.
Experimental Investigation on Turbulent Convection in Solar Air Heater Channel Fitted with Delta Winglet Vortex Generator
The paper presents an experimental study on the heat transfer and flow friction characteristics in a solar air heater channel fitted with delta-winglet type vortex generators (DWs). The experiments are conducted by varying the airflow rate for Reynolds number in the range of 5000 to 24000 in the test section with a uniform heat-flux applied on the upper channel wall. Firstly
the DW pairs are mounted only at the entrance of the lower wall of the test channel (called DW-E) to create multiple vortex flows at the entry. The effect of two transverse pitches (R
P
=P
t
/H=1 and 2) at three attack angles (α=30°
45° and 60°) of the DW-E with its relative height
b/H=0.5 (half height of channel) is examined. Secondly
the 30° DWs with three different relative heights (b/H 0.3
0.4 and 0.5) are placed on the upper wall only (absorber plate
called DW-A) of the test channel. The experimental result reveals that in the first case
the 60° DW-E at R
P
=1 provides the highest heat transfer and friction factor while the 30° DW-E at R
P
=1 performs overall better than the others. In the second case
the 30° DW-A at b/H=0.5 yields the highest heat transfer and friction factor but the best thermal
performance is found at b/H=0.4.
关键词
Keywords
references
The trial reading is over, you can activate your VIP account to continue reading.
Thermal performance assessment of self-rotating twisted tapes and Al2O3 nanoparticle in a circular pipe
A comprehensive study of two-phase flow and heat transfer of water/Ag nanofluid in an elliptical curved minichannel
Numerical study on the hydrodynamics of agglomerates at intermediate Reynolds numbers
Mixed convection characteristics in lid-driven cavity containing heated triangular block
Heat transfer and friction factor of Therminol liquid phase heat transfer fluid in a ribbed tube
相关作者
Shaojie Zhang
Tao Wen
Lin Lu
Chuanshuai Dong
Pouyan Talebizadehsardari
Saeid Mir
Ali Marzban
Ghanbarali Sheikhzadeh
相关机构
Department of Chemical Engineering, Imperial College London, London, United Kingdom
Department of Building Services Engineering, The Hong Kong Polytechnic University, 11 Yuk Choi Road, Hung Hom, Kowloon
Key Laboratory of Enhanced Heat Transfer and Energy Conservation of Education Ministry, School of Chemistry and Chemical Engineering, South China University of Technology
Faculty of Applied Sciences, Ton Duc Thang University, Ho Chi Minh City
Department for Management of Science and Technology Development, Ton Duc Thang University, Ho Chi Minh City