张吕鸿, 刘学宽, 李鑫钢, 等. A Novel SiC Foam Valve Tray for Distillation Columns[J]. 中国化学工程学报(英文版), 2013,21(8):821-8261004-954160552-2.
ZHANG Lühong, LIU Xuekuan, LI Xingang, GAO Xin, SUI Hong, ZHANG Jinsong, YANG Zhenming, TIAN Chong, LI Hong. A Novel SiC Foam Valve Tray for Distillation Columns[J]. Chin.J.Chem.Eng., 2013, 21(8): 821-826.
张吕鸿, 刘学宽, 李鑫钢, 等. A Novel SiC Foam Valve Tray for Distillation Columns[J]. 中国化学工程学报(英文版), 2013,21(8):821-8261004-954160552-2.DOI: 10.1016/S1004-9541(13)60552-2.
ZHANG Lühong, LIU Xuekuan, LI Xingang, GAO Xin, SUI Hong, ZHANG Jinsong, YANG Zhenming, TIAN Chong, LI Hong. A Novel SiC Foam Valve Tray for Distillation Columns[J]. Chin.J.Chem.Eng., 2013, 21(8): 821-826.DOI: 10.1016/S1004-9541(13)60552-2.
A Novel SiC Foam Valve Tray for Distillation Columns
The novel SiC foam valve tray was made of thin slices of SiC foam material with a high specific surface area. Hydrodynamic performances of the novel SiC foam valve tray were studied with air-water system at atmospheric pressure. These performance parameters included pressure drop
entrainment
weeping and clear liquid height. The mass transfer efficiency of the SiC foam valve tray was measured in laboratory plate column. Compared with the F1 float valve tray
the dry pressure drop was decreased about 25%
the entrainment rate was about 70% lower at high gas load
the weeping was much better
and the mass transfer efficiency was far higher. Thus
the overall performance of the novel SiC foam valve tray was better than that of F1 float valve tray.
关键词
Keywords
references