徐聪. Effects of Geometric Configurations on the Performance of Reverse Flow Diverters in Reverse Flow Mode[J]. 中国化学工程学报(英文版), 2012,20(5):856-862.
XU Cong. Effects of Geometric Configurations on the Performance of Reverse Flow Diverters in Reverse Flow Mode[J]. Chin.J.Chem.Eng., 2012, 20(5): 856-862.
徐聪. Effects of Geometric Configurations on the Performance of Reverse Flow Diverters in Reverse Flow Mode[J]. 中国化学工程学报(英文版), 2012,20(5):856-862.DOI: 10.1016/S1004-9541(12)60410-8.
XU Cong. Effects of Geometric Configurations on the Performance of Reverse Flow Diverters in Reverse Flow Mode[J]. Chin.J.Chem.Eng., 2012, 20(5): 856-862.DOI: 10.1016/S1004-9541(12)60410-8.
Effects of Geometric Configurations on the Performance of Reverse Flow Diverters in Reverse Flow Mode
The reverse flow diverter (RFD) consisting of a nozzle and a diffuser is a key component in pneumatic pulse jet pumps. We investigated the effects of suction gap and diffuser configurations on RFD performance during the reverse flow mode. Three suction gap configurations were examined: (1) an axisymmetrical cylinder
(2) a cuboid whose bottom plane had no half-circle groove and was level with the diffuser entrance lower border
and (3) a cuboid with a half-circle groove on the bottom plane. Among them
the second one resulted in the highest RFD pumping capacity. The effect of receiver presence before the diffuser was also examined. RFD pumping efficiency was found to be enhanced in the presence of a receiver before the diffuser when the suction gap length is small and the jet outlet velocity at the nozzle exit is high enough. Based on experimental data
a dimensionless performance curve of the suction factor
q
versus the ratio of Euler numbers in sections out-out and 0-0
E
u
out
/
E
u
0
was derived. This curve is insensitive to suction gap configurations.
关键词
Keywords
references
The trial reading is over, you can activate your VIP account to continue reading.