CO2 Capture by Vacuum Swing Adsorption Using F200 and Sorbead WS as Protective Pre-layers
|Updated:2026-01-06
|
CO2 Capture by Vacuum Swing Adsorption Using F200 and Sorbead WS as Protective Pre-layers
CO2 Capture by Vacuum Swing Adsorption Using F200 and Sorbead WS as Protective Pre-layers
中国化学工程学报(英文版)2012年20卷第5期 页码:849-855
Affiliations:
1. Guodian New Energy Technology Research Institute, China Guodian Corporation,Beijing,China,100034
2. Department of Chemical Engineering, Monash University,Melbourne,Australia,3186
3. School of Material and Metallurgy, Northeastern University,Shenyang,China,110004
Author bio:
Funds:
Supported by the National Natural Science Foundation of China (51074205);Corporate Research Centre for Greenhouse Gas Technology Foundation in Australia
徐冬, Penny Xiao, 李刚, 等. CO2 Capture by Vacuum Swing Adsorption Using F200 and Sorbead WS as Protective Pre-layers[J]. 中国化学工程学报(英文版), 2012,20(5):849-855. DOI: 10.1016/S1004-9541(12)60409-1.
Capture by Vacuum Swing Adsorption Using F200 and Sorbead WS as Protective Pre-layers[J]. Chinese Journal of Chemical Engineering, 2012, 20(5): 849-855.
徐冬, Penny Xiao, 李刚, 等. CO2 Capture by Vacuum Swing Adsorption Using F200 and Sorbead WS as Protective Pre-layers[J]. 中国化学工程学报(英文版), 2012,20(5):849-855. DOI: 10.1016/S1004-9541(12)60409-1.DOI:
Capture by Vacuum Swing Adsorption Using F200 and Sorbead WS as Protective Pre-layers[J]. Chinese Journal of Chemical Engineering, 2012, 20(5): 849-855.DOI: 10.1016/S1004-9541(12)60409-1.
CO2 Capture by Vacuum Swing Adsorption Using F200 and Sorbead WS as Protective Pre-layers
In order to solve the water issues when 13X zeolite was applied to capture CO
2
from wet flue gas by vacuum swing adsorption process
multi-layered adsorption system was considered regarding activated alumina F200 and silica gel based Sorbead WS as pre-layer materials. LBET (extended Largmuir-BET) model and extended CMMS (cooperative multimolecular sorption) equation were simulated respectively to describe water loading on F200 and Sorbead WS. The two equations can be well added into our in-house simulator to simulate double-layered CO
2
-VSA (vacuum swing adsorption) process. Results indicated that water can be successfully stopped in pre-layers with a good CO
2
capture performance.
关键词
Keywords
references