A Multi-level Approach for Complex Fault Isolation Based on Structured Residuals
|Updated:2026-01-06
|
A Multi-level Approach for Complex Fault Isolation Based on Structured Residuals
A Multi-level Approach for Complex Fault Isolation Based on Structured Residuals
中国化学工程学报(英文版)2011年19卷第3期 页码:462-472
Affiliations:
State Key Laboratory of Industrial Control Technology, Institute of Industrial Control Zhejiang University,Hangzhou,China,310027
Author bio:
Funds:
Supported by the National Natural Science Foundation of China(60574047);the National High Technology Research and Development Program of China (2007AA04Z168, 2009AA04Z154);the Research Fund for the Doctoral Program of Higher Education in China (20050335018)
叶鲁彬, 石向荣, 梁军. A Multi-level Approach for Complex Fault Isolation Based on Structured Residuals[J]. 中国化学工程学报(英文版), 2011,19(3):462-472.
YE Lubin, SHI Xiangrong, LIANG Jun. A Multi-level Approach for Complex Fault Isolation Based on Structured Residuals[J]. , 2011, 19(3): 462-472.
叶鲁彬, 石向荣, 梁军. A Multi-level Approach for Complex Fault Isolation Based on Structured Residuals[J]. 中国化学工程学报(英文版), 2011,19(3):462-472.DOI: 10.1016/S1004-9541(11)60007-4.
YE Lubin, SHI Xiangrong, LIANG Jun. A Multi-level Approach for Complex Fault Isolation Based on Structured Residuals[J]. , 2011, 19(3): 462-472.DOI: 10.1016/S1004-9541(11)60007-4.
A Multi-level Approach for Complex Fault Isolation Based on Structured Residuals
there exist faults that have complex effect on process variables.Complex and simple faults are defined according to their effect dimensions.The conventional approaches based on structured residuals cannot isolate complex faults.This paper presents a multi-level strategy for complex fault isolation.An extraction procedure is employed to reduce the complex faults to simple ones and assign them to several levels.On each level
faults are isolated by their different responses in the structured residuals.Each residual is obtained insensitive to one fault but more sensitive to others.The faults on different levels are verified to have different residual responses and will not be confused.An entire incidence matrix containing residual response characteristics of all faults is obtained
based on which faults can be isolated.The proposed method is applied in the Tennessee Eastman process example
and the effectiveness and advantage are demonstrated.
关键词
Keywords
references
The trial reading is over, you can activate your VIP account to continue reading.