Measurement and Correlation of Pressure Drop for Gas-Liquid Two-phase Flow in Rectangular Microchannels
|Updated:2026-01-06
|
Measurement and Correlation of Pressure Drop for Gas-Liquid Two-phase Flow in Rectangular Microchannels
Measurement and Correlation of Pressure Drop for Gas-Liquid Two-phase Flow in Rectangular Microchannels
中国化学工程学报(英文版)2010年18卷第6期 页码:940-947
Affiliations:
School of Chemical Engineering and Technology, State Key Laboratory of Chemical Engineering, Tianjin University,Tianjin,China,300072
Author bio:
Funds:
Supported by the National Natural Science Foundation of China (20876107);the Opening Project of State Key Laboratory of Chemical Engineering (SKL-ChE-08B06)
马友光, 季喜燕, 王东继, 等. Measurement and Correlation of Pressure Drop for Gas-Liquid Two-phase Flow in Rectangular Microchannels[J]. 中国化学工程学报(英文版), 2010,18(6):940-947.
MA Youguang, JI Xiyan, WANG Dongji, FU Taotao, ZHU Chunying. Measurement and Correlation of Pressure Drop for Gas-Liquid Two-phase Flow in Rectangular Microchannels[J]. , 2010, 18(6): 940-947.
马友光, 季喜燕, 王东继, 等. Measurement and Correlation of Pressure Drop for Gas-Liquid Two-phase Flow in Rectangular Microchannels[J]. 中国化学工程学报(英文版), 2010,18(6):940-947.DOI: 10.1016/S1004-9541(09)60151-8.
MA Youguang, JI Xiyan, WANG Dongji, FU Taotao, ZHU Chunying. Measurement and Correlation of Pressure Drop for Gas-Liquid Two-phase Flow in Rectangular Microchannels[J]. , 2010, 18(6): 940-947.DOI: 10.1016/S1004-9541(09)60151-8.
Measurement and Correlation of Pressure Drop for Gas-Liquid Two-phase Flow in Rectangular Microchannels
The pressure drop of gas-liquid two-phase flow in microchannel is of fundamental importance in heat and mass transfer processes. In this work
the pressure drop of gas-liquid two-phase flow in horizontal rectangular cross-section microchannels was measured by a pressure differential transducer system. Water
ethanol and
n
-propanol were used as liquid phase to study the effects of capillary number on pressure drop;air was used as the gas phase. Four microchannels with various dimensions of 100 μm×200 μm
100 μm×400 μm
100 μm×800 μm and 100 μm×2000 μm(depth×width) were used for determining the influence of configuration on the pressure drop. Experimental results showed that in micro-scale
the capillary number also affected the pressure drop remarkably
and in spite of only one-fold difference in aspect ratio
the variation of pressure drop reached up to near three times under the same experimental conditions. Taking the effects of aspect ratio and surface tension into account
a modified correlation for Chisholm parameter
C
in the Chisholm model was proposed for predicting the frictional multiplier
Φ
1
2
and the predicted values by the proposed correlation showed a satisfactory agreement with experimental data.
关键词
Keywords
references
The trial reading is over, you can activate your VIP account to continue reading.
Laminar flow of high-viscous non-Newtonian power-law and Bingham fluids in multiple structural bifurcation channel distributors: Flow patterns and pressure drop correlation
Pressure drop and gas holdup in an upward-flow fixed-bed reactor
Pressure drop force due to a non-closely fitting sphere settling along the central line in long rectangular tubes
A general pressure drop model based on liquid holdup of gas-liquid flow in micro-packed beds
A new hypothesis for cavitation nucleation in gas saturated solutions: Clustering of gas molecules lowers significantly the surface tension
相关作者
Xiaoyi Qiu
Xuesong Wang
Jie Jiang
Yuning Zhou
Wenze Guo
Zhenhao Xi
Ling Zhao
Weikang Yuan
相关机构
State Key Laboratory of Chemical Engineering and Low-Carbon Technology, East China University of Science and Technology
Key Laboratory of Smart Manufacturing in Energy Chemical Process, Ministry of Education, East China University of Science and Technology
Shanghai Key Laboratory of Multiphase Materials Chemical Engineering, East China University of Science and Technology
School of Mechanical and Power Engineering, East China University of Science and Technology