Absorption of NOx into Nitric Acid Solution in Rotating Packed Bed
|Updated:2026-01-06
|
Absorption of NOx into Nitric Acid Solution in Rotating Packed Bed
Absorption of NOx into Nitric Acid Solution in Rotating Packed Bed
中国化学工程学报(英文版)2010年18卷第2期 页码:244-248
Affiliations:
1. Research Center of Shanxi Province for High Gravity Engineering and Technology, Institute of Chemical Engineering and Environment, North University of China,Taiyuan,China,030051
2. Gansu Yinguang Chemical Group Co., Ltd.,Baiyin,China,730900
Author bio:
Funds:
Supported by the Fund of Science and Technology of Shanxi for Young Scholars(2007021012);Research Project of Shanxi Provincial Science and Technology Department(20090321113)
into nitric acid solutions was studied in the presence of ozone by using a rotating packed bed(RPB) contactor.The influences of operating parameters
such as high gravity number
amount of ozone
gas velocity
liquid spray density and inlet concentration of NO
x
on the removal efficiency of NO
x
were investigated
among which the high gravity number and ozone amount are more important.Ozone was introduced to oxidize HNO
2
to HNO
3
to prevent the decomposition of HNO
2
in the liquid phase.The high gravity number presents the effective external force for enhancing the mass transfer of ozone from gas phase to liquid phase.Under the experimental condition
the removal efficiency of NO
x
is higher than 90%and the concentration of nitric acid product exceeds 45%.
关键词