FOLLOWUS
1. Department of Environmental Engineering, Beijing Institute of Petrochemical Technology,Beijing,China,102617
2. Research Center for Eco-Environmental Engineering, Dongguan University of Technology,Dongguan,China,523808
纸质出版:2019
Scan QR Code
Lei Zhang, Mengyu Wu, Yanhe Han, 等. Structural parameter optimization for novel internal-loop iron-carbon micro-electrolysis reactors using computational fluid dynamics[J]. 中国化学工程学报(英文版), 2019,27(4):737-744.
Lei Zhang, Mengyu Wu, Yanhe Han, Meili Liu, Junfeng Niu. Structural parameter optimization for novel internal-loop iron-carbon micro-electrolysis reactors using computational fluid dynamics[J]. Chinese Journal of Chemical Engineering, 2019, 27(4): 737-744.
Lei Zhang, Mengyu Wu, Yanhe Han, 等. Structural parameter optimization for novel internal-loop iron-carbon micro-electrolysis reactors using computational fluid dynamics[J]. 中国化学工程学报(英文版), 2019,27(4):737-744. DOI:
Lei Zhang, Mengyu Wu, Yanhe Han, Meili Liu, Junfeng Niu. Structural parameter optimization for novel internal-loop iron-carbon micro-electrolysis reactors using computational fluid dynamics[J]. Chinese Journal of Chemical Engineering, 2019, 27(4): 737-744. DOI:
It is generally recognized that internal-loop reactors are well-developed mass and heat-transfer multiphase flow reactors. However
the internal flow field in the internal-loop reactor is influenced by the structure parameter of the reactor
which has a great effect on the reaction efficiency. In this study
the computational fluid dynamics simulation method was used to determine the influence of reactor structure on flow field
and a volume-offluid model was employed to simulate the gas-liquid
two-phase flow of the internal-loop micro-electrolysis reactor. Hydrodynamic factors were optimized when the height-to-diameter ratio was 4:1
diameter ratio was 9:1
draft-tube axial height was 90 mm. Three-dimensional simulations for the water distributor were carried out
and the results suggested that the optimal conditions are as follows:the number of water distribution pipes was four
and an inhomogeneous water distribution was used. According to the results of the simulation
the suitable structure can be used to achieve good fluid mechanical properties
such as the good liquid circulation velocity and gas holdup
which provides a good theoretical foundation for the application of the reactor.