Effects of Sn residue on the high temperature stability of the H2-permeable palladium membranes prepared by electroless plating on Al2O3 substrate after SnCl2 PdCl2 process: A case study
Separation Science and Engineering|Updated:2026-01-06
|
Effects of Sn residue on the high temperature stability of the H2-permeable palladium membranes prepared by electroless plating on Al2O3 substrate after SnCl2 PdCl2 process: A case study
Effects of Sn residue on the high temperature stability of the H2-permeable palladium membranes prepared by electroless plating on Al2O3 substrate after SnCl2 PdCl2 process: A case study
中国化学工程学报(英文版)2016年24卷第9期 页码:1154-1160
Affiliations:
State Key Laboratory of Materials-oriented Chemical Engineering, College of Chemical Engineering, Nanjing Tech University,Nanjing,China,210009
Author bio:
Funds:
DOI:
中图分类号:10.1016/j.cjche.2016.04.008
纸质出版:2016
Accepted:
Scan QR Code
LeiWei, Jian Yu, Xiaojuan Hu, 等. Effects of Sn residue on the high temperature stability of the H2-permeable palladium membranes prepared by electroless plating on Al2O3 substrate after SnCl2 PdCl2 process: A case study[J]. 中国化学工程学报(英文版), 2016,24(9):1154-1160.
-permeable palladium membranes prepared by electroless plating on Al
LeiWei, Jian Yu, Xiaojuan Hu, 等. Effects of Sn residue on the high temperature stability of the H2-permeable palladium membranes prepared by electroless plating on Al2O3 substrate after SnCl2 PdCl2 process: A case study[J]. 中国化学工程学报(英文版), 2016,24(9):1154-1160.DOI:
-permeable palladium membranes prepared by electroless plating on AlDOI:
Effects of Sn residue on the high temperature stability of the H2-permeable palladium membranes prepared by electroless plating on Al2O3 substrate after SnCl2 PdCl2 process: A case study
摘要
中图分类号:
Abstract
The stability of composite palladium membranes is of key importance for their application in hydrogen energy systems. Most of these membranes are prepared by electroless plating
and beforehand the substrate surface is activated by a SnCl
2
-PdCl
2
process
but this process leads to a residue of Sn
which has been reported to be harmful to the membrane stability. In this work
the Pd/Al
2
O
3
membranes were prepared by electroless plating after the SnCl
2
-PdCl
2
process. The amount of Sn residue was adjusted by the SnCl
2
concentration
activation times and additional Sn(OH)
2
coating. The surface morphology
cross-sectional structure and elemental composition were analyzed by scanning electron microscopy (SEM)
metallography and energy dispersive spectroscopy (EDS)
respectively. Hydrogen permeation stability of the prepared palladium membranes were tested
at 450-600℃ for 400 h. It was found that the higher SnCl
2
concentration and activation times enlarged the Sn residue amount and led to a lower initial selectivity but a better membrane stability. Moreover
the additional Sn(OH)
2
coating on the Al
2
O
3
substrate surface also greatly improved the membrane selectivity and stability. Therefore
it can be concluded that the Sn residue from the SnCl
2
-PdCl
2
process cannot be a main factor for the stability of the composite palladium membranes at high temperatures.
关键词
Keywords
references
The trial reading is over, you can activate your VIP account to continue reading.
Preparation of a zeolite-palladium composite membrane for hydrogen separation: Influence of zeolite film on membrane stability
Effect of additives on nickel-phosphorus deposition obtained by electroless plating: Characterization and corrosion resistance in 3%(mass) sodium chloride medium
Analysis of H2S Tolerance of Pd-Cu Alloy Hydrogen Separation Membranes
Revealing critical factors in lignite-water interactions: From atomic to macroscopic
Understanding temperature-dependent degradation in proton exchange membrane water electrolyzer: The critical role of porous transport layer
相关作者
Hongmei Wu
Xinyu Liu
Yu Guo
N. M'hanni
T. Anik
R. Touir
M. Galai
M. Ebn Touhami
相关机构
School of Chemical and Environmental Engineering, Liaoning University of Technology
Advanced Materials and Process Engineering Laboratory, Faculty of Sciences, Ibn Tofail University, BP 133, 14 Kenitra
Regional Center for Education and Training Professions (CRMEF), Kenitra
Laboratory of Molecular Engineering Applied to the Analysis, IPHC, UMR 7178 CNRS, University of Strasbourg, ECPM, 25 Street Becquerel, Strasbourg Cedex 2
Laboratoire de Chimie Analytique et Moléculaire/LCAM, Université Cadi Ayyad, Faculté Polydisciplinaire, Sidi Bouzid, B.P. 4162, 46 Safi