2 School of Applied Sciences, Netaji Subhas Institute of Technology, University of Delhi,New Delhi,India,110075
Author bio:
Funds:
DOI:
中图分类号:
纸质出版:2014
Accepted:
Scan QR Code
Sulekh Chandra, Deepshikha Singh, Anjana Sarkar. PVC Membrane Selective Electrode for Determination of Cadmium(Ⅱ) Ion in Chocolate Samples[J]. 中国化学工程学报(英文版), 2014,22(4):480-4881004-954160055-0.
Sulekh Chandra, Deepshikha Singh, Anjana Sarkar. PVC Membrane Selective Electrode for Determination of Cadmium(Ⅱ) Ion in Chocolate Samples[J]. Chin.J.Chem.Eng., 2014, 22(4): 480-488.
Sulekh Chandra, Deepshikha Singh, Anjana Sarkar. PVC Membrane Selective Electrode for Determination of Cadmium(Ⅱ) Ion in Chocolate Samples[J]. 中国化学工程学报(英文版), 2014,22(4):480-4881004-954160055-0.DOI:
Sulekh Chandra, Deepshikha Singh, Anjana Sarkar. PVC Membrane Selective Electrode for Determination of Cadmium(Ⅱ) Ion in Chocolate Samples[J]. Chin.J.Chem.Eng., 2014, 22(4): 480-488.DOI:
PVC Membrane Selective Electrode for Determination of Cadmium(Ⅱ) Ion in Chocolate Samples
摘要
Abstract
Benzil bis(carbohydrazone) (BBC) is prepared and explored as new N—N Schiff's base
which plays the role of an excellent ion carrier in the construction of a Cd(Ⅱ) ion membrane sensor. The tris(2-ethylhexyl) phosphate best performance corresponds to a membrane composition of 30% poly (vinyl chloride)
65% (TEHP)
3.5% BBC and 1.5% tetradodecyl-ammoniumtetrakis(4-chlorophenyl) borate (ETH 500). This sensor shows very good selectivity and sensitivity towards cadmium ion over a wide variety of cations
including alkali
alkaline earth
transition and heavy metal ions. The effect of membrane composition
selectivity
pH and influence of additive on the response properties of electrode were investigated. The response mechanism was discussed in the view of UV-spectroscopy. The electrode exhibits a Nernstian behavior (with slope of 29.7 mV per decade) over a very wide concentration range from 1.0×10
-1
to 1.0×10
-8
mol·L
-1
with a detection limit of 3.2×10
-8
mol·L
-1
. It shows relatively fast response time in whole concentration range (8 s) and can be used for at least 10 weeks in the pH range of 2.0-9.0. The proposed sensor is successfully used for the determination of cadmium in different chocolate
samples and as indicator electrode in titration with ethylene diamine tetraacetate (EDTA).
关键词
Keywords
references
The trial reading is over, you can activate your VIP account to continue reading.
Charge transfer mediator additive facilitates uniform lithium deposition in ester-based electrolytes
Effects of Additives and Coagulant Temperature on Fabrication of High Performance PVDF/Pluronic F127 Blend Hollow Fiber Membranes via Nonsolvent Induced Phase Separation
Effect of Aminoaromatic Acids as Additives on the Activity and Selectivity of the Platinum-catalyzed Hydrosilylation of Alkenes
Effect of Additive EDTA on Crystallization Process of Magnesium Hydroxide Precipitation
Enhanced mass transfer in flexible electrodes of open-pore cobalt disulfide nanosheets supported on sulfur-doped carbon fibers for efficient zinc-air batteries
相关作者
Liu Peng
Wang Xiaolong
Zhou Henghui
Jiang Peng
Yan Yi
Zhang Yujia
Li Yaoyu
Wang Yidan
相关机构
China Huaneng Clean Energy Research Institute, Future Science Park
CAS Key Laboratory of Standardization and Measurement for Nanotechnology, CAS Center for Excellence in Nanoscience, National Center for Nanoscience and Technology
University of Chinese Academy of Sciences
College of Chemistry and Molecular Engineering, Peking University
School of Civil and Environmental Engineering, Nanyang Technological University