方立德, 张涛. Performance of a Horizontally Mounted Venturi in Low-pressure Wet Gas Flow[J]. 中国化学工程学报(英文版), 2008,16(2):320-324.
FANG Lide, ZHANG Tao. Performance of a Horizontally Mounted Venturi in Low-pressure Wet Gas Flow[J]. , 2008, 16(2): 320-324.
方立德, 张涛. Performance of a Horizontally Mounted Venturi in Low-pressure Wet Gas Flow[J]. 中国化学工程学报(英文版), 2008,16(2):320-324. DOI:
FANG Lide, ZHANG Tao. Performance of a Horizontally Mounted Venturi in Low-pressure Wet Gas Flow[J]. , 2008, 16(2): 320-324. DOI:
The performance of a Venturi tube used in wet gas flow have been explored mainly under higher-pressure condition
but very often
low-pressure test exists in some oil and gas fields in Tianjin Dagang Oil and Gas Field in China.In this study
the performance of horizontally mounted Venturi meters in low-pressure wet gas flow is discussed.Three 50 mm Venturi meters were tested systematically
withβvalues of 0.4048
0.55 and 0.70
the operation pressure of 0.15 MPa
0.20 MPa
0.25 MPa
the gas densiometric Froude number from 0.6 to 2.0
the modified Lockhart-Maretinelli parameter from 0.0022 to 0.06
and the ratio of the gas liquid mass flow rate from 0.5 to 0.99. The effects of modified Lockhart-Maretinelli parameter
pressure
gas densiometric Froude number
diameter ratio
and gas-liquid mass flow rate ratio to the Venturi tube are analyzed with new independent data.Furthermore
low-pressure performance was compared with that under high pressure.