Design and Experimental Analyses of Small-flow High-head Centrifugal-vortex Pump for Gas-Liquid Two-phase Mixture
|Updated:2026-01-06
|
Design and Experimental Analyses of Small-flow High-head Centrifugal-vortex Pump for Gas-Liquid Two-phase Mixture
Design and Experimental Analyses of Small-flow High-head Centrifugal-vortex Pump for Gas-Liquid Two-phase Mixture
中国化学工程学报(英文版)2008年16卷第4期 页码:528-534
Affiliations:
Zhejiang Provincial Key Laboratory of Modern Textile Machinery, Zhejiang Sci-Tech University,Hangzhou,China,310018
Author bio:
Funds:
the National Natural Science Foundation of China(50576088,20706049);Zhejiang Provincial Key Science Foundation(2006C21064,2007C21067)
DOI:
中图分类号:
纸质出版:2008
Accepted:
Scan QR Code
朱祖超, 谢鹏, 偶国富, 等. Design and Experimental Analyses of Small-flow High-head Centrifugal-vortex Pump for Gas-Liquid Two-phase Mixture[J]. 中国化学工程学报(英文版), 2008,16(4):528-534.
ZHU Zuchao, XIE Peng, OU Guofu, CUI Baoling, LI Yi. Design and Experimental Analyses of Small-flow High-head Centrifugal-vortex Pump for Gas-Liquid Two-phase Mixture[J]. , 2008, 16(4): 528-534.
朱祖超, 谢鹏, 偶国富, 等. Design and Experimental Analyses of Small-flow High-head Centrifugal-vortex Pump for Gas-Liquid Two-phase Mixture[J]. 中国化学工程学报(英文版), 2008,16(4):528-534.DOI:
ZHU Zuchao, XIE Peng, OU Guofu, CUI Baoling, LI Yi. Design and Experimental Analyses of Small-flow High-head Centrifugal-vortex Pump for Gas-Liquid Two-phase Mixture[J]. , 2008, 16(4): 528-534.DOI:
Design and Experimental Analyses of Small-flow High-head Centrifugal-vortex Pump for Gas-Liquid Two-phase Mixture
The design method of small-flow high-head centrifugal-vortex pump was presented. This pump
configured with inducer
complex-centrifugal impeller and open-vortex impeller
was put forward to deliver gas-liquid two-phase mixture. An HTB-5/60 type sample pump was developed and tested on a closed-loop test rig. Experimental studies on performance and cavitation tests for gas-liquid two-phase mixture were carried out compared with pure-water experimental results. Also the effect of gas phase on pump was analyzed and discussed. The experimental results show that performance and cavitation characteristics of the sample pump deteriorates progressively with increasing volume fraction of gas. When the total capacity
Q
m
is between 4.5 m
3
·h
-1
and 6 m
3
·h
-1
and the gas flow rate
q
g
below 0.66 m
3
·h
-1
or
q
g
/
Q
m
is lower than 15%
the characteristic curves are approximately parallel to those in pure water test
but the performance deteriorates sharply until an abrupt flow-cutting at a critical volume fraction of gas. This pump is found suitable for transporting gas-liquid two-phase mixture when working around rated capacity of 5 m
3
·h
-1
with
q
g
/
Q
m
below 15%.
关键词
Keywords
references
The trial reading is over, you can activate your VIP account to continue reading.