Flame retardant synergy between interfacial and bulk carbonation in glass fiber reinforced polypropylene
Materials and Product Engineering|Updated:2026-01-06
|
Flame retardant synergy between interfacial and bulk carbonation in glass fiber reinforced polypropylene
Chinese Journal of Chemical EngineeringIssue 6, Pages: 1725-1732(2020)
Affiliations:
Shanghai Engineering Research Center of Hierarchical Nanomaterials, Key Laboratory for Ultrafine Materials of Ministry of Education, School of Materials Science and Engineering, East China University of Science & Technology,Shanghai,China,200237
Yuan Xue, Rongjing Zhao, Ling Zhang, et al. Flame retardant synergy between interfacial and bulk carbonation in glass fiber reinforced polypropylene[J]. Chinese Journal of Chemical Engineering, 2020, (6): 1725-1732.
DOI:
Yuan Xue, Rongjing Zhao, Ling Zhang, et al. Flame retardant synergy between interfacial and bulk carbonation in glass fiber reinforced polypropylene[J]. Chinese Journal of Chemical Engineering, 2020, (6): 1725-1732.DOI: 10.1016/j.cjche.2020.03.034.
Flame retardant synergy between interfacial and bulk carbonation in glass fiber reinforced polypropylene
Glass fiber reinforced polypropylene (GF-PP) composites have high flammability on account of wick effect which leads to accelerated flow of the polymer melt along the glass fibers (GF) surface to the flame zone. In this study
dipentaerythritol (DPER)
a charring agent
was adsorbed on the GF surface through the hydrogen bond between silane coupling agent and DPER. DPER has a synergistic effect with the intumescent flame retardants (IFR) added in the composites
which can induce interfacial carbonization on the surface of GF
thus transforming the intrinsic smooth GF surface into roughness one. In this way
the negative effect of the wick effect in flame retardancy is weakened. Moreover
the char residues remained on the surface of GF can bring an improved adhesion between GF and char residues formed in the resin so that a more stable barrier char layer is formed. The PP composites with 20 wt% modified glass fiber (M-GF) and 30 wt% IFR can achieve the UL-94V-0
and its limiting oxygen index (LOI) value increased from 16.5% to 29.5%. Simultaneously
the heat release rate (HRR)
total heat release (THR) and total smoke release (TSR) decreased significantly
and the peak of heat release rate (PHRR) reduced 60.6% compared with GF-PP.
关键词
Keywords
references
The trial reading is over, you can activate your VIP account to continue reading.
Boron nitride silicone rubber composite foam with low dielectric and high thermal conductivity
Microencapsulated ammonium polyphosphate by polyurethane with segment of dipentaerythritol and its application in flame retardant polypropylene
Tailoring the molecular structure of cross-linked poly(ethylene oxide) membranes for enhanced CO2 permeation
Preparation of novel hierarchical porous Fe2O3/SBA-15 with microporous plugs from coal gasification fine residue and its degradation of phenol in coal chemical wastewater
Enhanced plasma-catalytic steam reforming of methane to methanol on a hydrophobically modified Cu/silicalite-1 catalyst
Related Author
Shuilai Qiu
Hang Wu
Fukai Chu
Lei Song
Shouwu Yu
Shujuan Xiao
Zewen Zhao
Xiaowen Huo
Related Institution
College of Safety and Ocean Engineering, China University of Petroleum-, Beijing
State Key Laboratory of Fire Science, University of Science and Technology of China
School of Material Science and Engineering, Tianjin Polytechnic University
College of Materials Science and Engineering, North China University of Science and Technology