Effects of Pulse Ultrasound on Adsorption of Geniposide on Resin 1300 in a Fixed Bed
The effects of pulse ultrasound with different pulse parameters on the breakthrough curves of Geniposide on Resin 1300 were studied. The mass transfer model describing the adsorption process was constructed. Adsorption capability and the overall mass-transfer coefficient were obtained by fitting the constructed mass-transfer model and the experimental data. The effects of pulse ultrasound on adsorption of Geniposide on Resin1300 in a fixed bed were studied and compared. Amount of Geniposide adsorbed on Resin 1300 in the presence of ultrasound is lower than that in the absence of ultrasound
but the mass-transfer rate with ultrasonic irradiation is higher than that without ultrasound. Furthermore
mass transfer rate is enhanced by pulse modulation. In the conditions studied
the adsorption equilibrium constant decreases with increasing ultrasonic power
while the overall mass-transfer coefficient increases. With increasing pulse duty ratio