On-line Monitoring for Phosphorus Removal Process and Bacterial Community in Sequencing Batch Reactor
|Updated:2026-01-06
|
On-line Monitoring for Phosphorus Removal Process and Bacterial Community in Sequencing Batch Reactor
Chinese Journal of Chemical EngineeringVol. 17, Issue 3, Pages: 484-492(2009)
Affiliations:
1. Key Laboratory of Beijing for Water Quality Science and Water Environment Recovery Engineering, Beijing University of Technology,Beijing,China,100124
2. China Aeronautical Project and Design Institute,Beijing,China,100011
CUI Youwei, WANG Shuying, LI Jing. On-line Monitoring for Phosphorus Removal Process and Bacterial Community in Sequencing Batch Reactor[J]. , 2009, 17(3): 484-492.
DOI:
CUI Youwei, WANG Shuying, LI Jing. On-line Monitoring for Phosphorus Removal Process and Bacterial Community in Sequencing Batch Reactor[J]. , 2009, 17(3): 484-492.DOI: 10.1016/S1004-9541(08)60235-9.
On-line Monitoring for Phosphorus Removal Process and Bacterial Community in Sequencing Batch Reactor
For efficient energy consumption and control of effluent quality
the cycle duration for a sequencing batch reactor (SBR) needs to be adjusted by real-time control according to the characteristics and loading of wastewater. In this study
an on-line information system for phosphorus removal processes was established. Based on the analysis for four systems with different ecological community structures and two operation modes
anaerobic-aerobic process and anaerobic-anaerobic process
the characteristic patterns of oxidation-reduction potential (ORP) and pH were related to phosphorous dynamics in the anaerobic
anoxic and aerobic phases
for determination of the end of phosphorous removal. In the operation mode of anaerobic-aerobic process
the pH profile in the anaerobic phase was used to estimate the relative amount of phosphorous accumulating organisms (PAOs) and glycogen accumulating organisms (GAOs)
which is beneficial to early detection of ecology community shifts. The on-line sensor values of pH and ORP may be used as the parameters to adjust the duration for phosphorous removal and community shifts to cope with influent variations and maintain appropriate operation conditions.
关键词
Keywords
references
The trial reading is over, you can activate your VIP account to continue reading.
Performance evaluation of polyamide nanofiltration membranes for phosphorus removal process and their stability against strong acid/alkali solution
Protein retention in dextran-grafted cation exchange chromatography: The influence of pHs, counterions and polymer structure
Osmotic concentration of succinic acid by forward osmosis: Influence of feed solution pH and evaluation of seawater as draw solution
Investigation on the Key Factors and the Solution for pH Value Decrease in Carbon Filter in O3-BAC Process
Nitrite Accumulation during the Denitrification Process in SBR for the Treatment of Pre-treated Landfill Leachate
Related Author
Ahmad Fauzi Ismail
Soon Onn Lai
Woei Jye Lau
Chai Hoon Koo
How Chun Lam
Yen Khai Chai
Qinghong Shi
Run Liu
Related Institution
Department of Civil Engineering, Lee Kong Chian Faculty of Engineering and Science, Universiti Tunku Abdul Rahman, Jalan Bandar Sg. Long, Bandar Sg. Long, Kajang
Advanced Membrane Technology Research Centre (AMTEC), Universiti Teknologi Malaysia, Skudai
Department of Chemical Engineering, Lee Kong Chian Faculty of Engineering and Science, Universiti Tunku Abdul Rahman, Jalan Bandar Sg. Long, Bandar Sg. Long, Kajang
Department of Biochemical Engineering, School of Chemical Engineering and Technology, Tianjin University
Key Laboratory of Systems Bioengineering, Ministry of Education, Tianjin University