Comparative study on pressure swing adsorption system for industrial hydrogen and fuel cell hydrogen
Recent Advances in Adsorptive Separation Materials and Technologies|Updated:2026-01-06
|
Comparative study on pressure swing adsorption system for industrial hydrogen and fuel cell hydrogen
Chinese Journal of Chemical EngineeringVol. 42, Issue 2, Pages: 112-119(2022)
Affiliations:
Southwest Institute of Chemical Co., Ltd.,Chengdu,China,610225
Author bio:
Funds:
DOI:
CLC:
Published:2022
Accepted:
Scan QR Code
Jian Chen, Lingbing Bu, Yingqi Luo. Comparative study on pressure swing adsorption system for industrial hydrogen and fuel cell hydrogen[J]. Chinese Journal of Chemical Engineering, 2022, 42(2): 112-119.
DOI:
Jian Chen, Lingbing Bu, Yingqi Luo. Comparative study on pressure swing adsorption system for industrial hydrogen and fuel cell hydrogen[J]. Chinese Journal of Chemical Engineering, 2022, 42(2): 112-119.DOI:
Comparative study on pressure swing adsorption system for industrial hydrogen and fuel cell hydrogen
In order to improve the design of PSA system for fuel cell hydrogen production
a non-isothermal model of eight-bed PSA hydrogen process with five-component (H
2
/N
2
/CH
4
/CO/CO
2
=74.59%/0.01%/4.2%/2.5%/18.7% (vol)) four-stage pressure equalization was developed in this article. The model adopts a composite adsorption bed of activated carbon and zeolite 5A. In this article
pressure variation
temperature field and separation performance are stimulated
and also effect of providing purge (PP) differential pressure and the ratio of activated carbon to zeolite 5A on separation performance in the process of producing industrial hydrogen (CO content in hydrogen is 10 μl·L
-1
) and fuel cell hydrogen (CO content is 0.2 μl·L
-1
) are compared. The results show that Run 3
when the CO content in hydrogen is 10 μl·L
-1
the hydrogen recovery is 89.8%
and the average flow rate of feed gas is 0.529 mol·s
-1
; When the CO content in hydrogen is 0.2 μl·L
-1
the hydrogen recovery is 85.2%
and the average flow rate of feed gas is 0.43 mol·s
-1
. With the increase of PP differential pressure
hydrogen recovery first increases and then decreases
reaching the maximum when PP differential pressure is 0.263 MPa; With the decrease of the ratio of activated carbon to zeolite 5A
the hydrogen recovery increases gradually. When the CO content in hydrogen is 0.2 μl·L
-1
the hydrogen recovery increases more obviously
from 83.96% to 86.37%
until the ratio of activated carbon to zeolite 5A decreases to 1. At the end of PP step
no large amount of CO
2
in gas or solid phase enters the zeolite 5A adsorption bed
while when the CO content in hydrogen is 10 μl·L
-1
and the ratio of carbon to zeolite 5A is less than 1.4
more CO
2
will enter the zeolite 5A bed.
关键词
Keywords
references
The trial reading is over, you can activate your VIP account to continue reading.