Local component based principal component analysis model for multimode process monitoring
Process Systems Engineering and Process Safety|Updated:2026-01-06
|
Local component based principal component analysis model for multimode process monitoring
Chinese Journal of Chemical EngineeringVol. 34, Issue 6, Pages: 116-124(2021)
Affiliations:
Department of Information Engineering, Shenyang University of Chemical Technology,Shenyang,China,110142
Author bio:
Funds:
DOI:
CLC:
Published:2021
Accepted:
Scan QR Code
Yuan Li, Dongsheng Yang. Local component based principal component analysis model for multimode process monitoring[J]. Chinese Journal of Chemical Engineering, 2021, 34(6): 116-124.
DOI:
Yuan Li, Dongsheng Yang. Local component based principal component analysis model for multimode process monitoring[J]. Chinese Journal of Chemical Engineering, 2021, 34(6): 116-124.DOI:
Local component based principal component analysis model for multimode process monitoring
For plant-wide processes with multiple operating conditions
the multimode feature imposes some chal lenges to conventional monitoring techniques. Hence
to solve this problem
this paper provides a novel local component based principal component analysis (LCPCA) approach for monitoring the status of a multimode process. In LCPCA
the process prior knowledge of mode division is not required and it purely based on the process data. Firstly
LCPCA divides the processes data into multiple local components using finite Gaussian mixture model mixture (FGMM). Then
calculating the posterior probability is applied to determine each sample belonging to which local component. After that
the local component information (such as mean and standard deviation) is used to standardize each sample of local component. Finally
the standardized samples of each local component are combined to train PCA monitoring model. Based on the PCA monitoring model
two monitoring statistics
T
2
and SPE are used for monitoring multimode pro cesses. Through a numerical example and the Tennessee Eastman (TE) process
the monitoring result demonstrates that LCPCA outperformed conventional PCA
and LNS-PCA in the fault detection rate.